Home›Repair guides›Wacker Neuson›Connecting an External Fuel Supply

Wacker Neuson G 25 — Connecting an External Fuel Supply

Installation · Fuel system

For the Wacker Neuson G 25, from the Wacker Neuson owner's manual.

Applies to: Wacker Neuson G 25

Before you start

  • Fire hazard. Ensure quick-disconnect fittings are seated and hoses are not kinked.

Procedure

  1. Connect the external feed hose at the external feed hose fitting.
  2. Connect the external return hose at the external return hose fitting.
  3. Move the fuel valve handle from the up position for internal supply to the down position for external supply.

Specs & values

  • Fitting size ISO 7241-1-Series B (supply 1/2 in., return 3/8 in.)

Source: Wacker Neuson owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.