Procedure

  1. Set the multimeter for diode measurement.
  2. Connect the test probes between the stator body and one of the three stator windings.
  3. The instrument should read OL; any other value indicates the stator is short-circuited.

Tools required

  • Multimeter (diode measurement) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • OL expected

Source: Volvo Penta service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.