Home›Repair guides›Volvo Penta›Functionality check of relays

Volvo Penta Group 23 EDC III — Functionality check of relays

Testing & diagnosis · Relays (main relay)

For the Volvo Penta Group 23 EDC III, from the Volvo Penta service manual.

Browse Volvo Penta generators & specs →

Procedure

  1. Disconnect the main relay from the engine.
  2. Measure between pins 87a and 30 (high frequency); multimeter should emit an alarm.
  3. Measure between pins 87 and 30; multimeter should not emit an alarm.
  4. Measure resistance between pins 85 and 86; should read 240–270 Ω.
  5. Connect 24V between pins 85 and 86; measure between pins 87 and 30 (should alarm).
  6. Connect 24V between pins 85 and 86; measure between pins 87a and 30 (should not alarm).
  7. Replace the relay if test results do not match.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Pins 85–86: 240–270 Ω

Source: Volvo Penta service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.