Home›Repair guides›Volvo Penta›Fault detection on unit injectors

Volvo Penta Group 23 EDC III — Fault detection on unit injectors

Testing & diagnosis

For the Volvo Penta Group 23 EDC III, from the Volvo Penta service manual.

Browse Volvo Penta generators & specs →

Procedure

  1. Perform a relative compression test on the cylinders (value below 80% indicates a compression error; test three times).
  2. Perform an injector test (switch off one injector at a time; engine noise level should change).
  3. Perform a relative acceleration test (lower engine speed when measuring; compare cylinder results).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Relative compression limit values 80%–100%

Source: Volvo Penta service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.