Procedure

  1. Switch off the engine.
  2. Disconnect connector; connect 4-pin adapter 9998534 between sensor connector and engine wiring; connect multimeter between points 1-4.
  3. Switch on operating voltage; check multimeter reads 5.0 volts.
  4. Connect multimeter between points 2-4; voltage should be about 1.2 V at normal atmospheric pressure.
  5. For temperature: connect adapter 9998534 between sensor connector and multimeter; measure resistance between adapter points.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Points 1-4: 5.0 V
  • Points 2-4: ~1.2 V at atmospheric pressure
  • Temperature points 3-4: R~6.2 kΩ (20°C / 68°F)
  • Temperature points 3-4: R~2.5 kΩ (40°C / 104°F)

Source: Volvo Penta service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.