Volvo Penta — Front crankshaft seal, replacement
Repair & overhaul
From a Volvo Penta service manual — check it applies to your exact model before use.
Browse Volvo Penta generators & specs →
Before you start
- The vibration damper must not be exposed to knocks or blows.
Procedure
- Remove fan and drive belts.
- Remove pulley and vibration damper.
- Remove polygon hub centre screw, remove washer, pull off hub with extractor 2655.
- Tap sealing ring to angle it out; bend out with a screwdriver.
- Oil in the new sealing ring and fit it with drift 6795.
- Fit polygon hub and vibration damper.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Volvo Penta service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.