Home›Repair guides›Volvo Penta›Cylinder head tightening (61 and 71 series)

Volvo Penta — Cylinder head tightening (61 and 71 series)

Adjustments · Cylinder head bolts

From a Volvo Penta service manual — check it applies to your exact model before use.

Browse Volvo Penta generators & specs →

Before you start

  • Cylinder head bolts must be dipped completely (including bolt heads) in a rustproofing compound a maximum of 24 hours prior to assembly.
  • The bolts should not drip at all when fitted.

Procedure

  1. 1st tightening: 30 Nm (3 kpm/21.7 lbf.ft) in numbered sequence.
  2. 2nd tightening 61 series: 85 Nm (8.5 kpm/61 lbf.ft) in numbered sequence.
  3. 2nd tightening 71 series: 90 Nm (9 kpm/65 lbf.ft) in numbered sequence.
  4. 3rd tightening 61 series: 85 Nm (8.5 kpm/61 lbf.ft) in numbered sequence (torque check).
  5. 3rd tightening 71 series: 90 Nm (9 kpm/65 lbf.ft) in numbered sequence (torque check).
  6. Final tightening: angle tighten the bolts 60 degrees in numbered sequence.

Specs & values

  • 30 Nm first stage
  • 85 Nm 61 series
  • 90 Nm 71 series
  • 60 degrees final angle tightening

Source: Volvo Penta service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Volvo Penta repair guides →