Home›Repair guides›Volvo Penta›Adjusting the valves

Volvo Penta — Adjusting the valves

Adjustments · Valve mechanism / rocker arms

From a Volvo Penta service manual — check it applies to your exact model before use.

Browse Volvo Penta generators & specs →

Before you start

  • The valves must never be adjusted while the engine is running

Procedure

  1. Remove the rocker arm casings.
  2. Adjust valve clearances on cylinder no. 1 in its firing position; no. 6 valves will then rock.
  3. Turn the engine one third of a revolution in its direction of rotation; check cylinder no. 5.
  4. Continue in firing order 1-5-3-6-2-4, referenced to the rocking cylinder.
  5. Set inlet 0.40 mm and exhaust 0.70 mm.
  6. Clean and refit the rocker arm casings with new gaskets and check for oil leaks.

Specs & values

  • Inlet 0.40 mm (0.016 in)
  • Exhaust 0.70 mm (0.028 in)

Source: Volvo Penta service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.