Home›Repair guides›Perkins›Coolant (ELC) - Change

Perkins — Coolant (ELC) - Change

Maintenance · Cooling system

From a Perkins operator's manual covering: 1106C-70TA, 1106D-70TA, SEBU8731. Check it applies to your exact model before use.

Applies to: Perkins 1106C-70TA, Perkins 1106D-70TA

Before you start

  • Pressurized System: Hot coolant can cause serious burns
  • Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks

Procedure

  1. Drain: stop engine, allow to cool, loosen filler cap slowly, remove cap; open drain cock or remove drain plug (1) on engine and radiator; allow coolant to drain.
  2. Flush: flush system with clean water; close drain cock/install drain plug.
  3. Fill with clean water, install filler cap; run engine at low idle until 49 to 66 °C (120 to 150 °F).
  4. Stop, cool, remove cap, drain water, flush with clean water.
  5. Fill: close drain cock/install drain plug; fill with ELC; do not install filler cap.
  6. Start and run at low idle; increase to high idle for 1 minute to purge air; decrease to low idle; stop engine.
  7. Check coolant level; maintain within 13 mm (0.5 inch) below bottom of filler pipe.
  8. Clean and inspect the filler cap gasket; pressure test or replace if damaged.
  9. Start the engine; inspect cooling system for leaks and correct operating temperature.

Tools required

  • Suitable pressurizing pump for filler cap test Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Do not fill faster than 5 L (1.3 US gal) per minute
  • Warm engine to 49 to 66 °C (120 to 150 °F)
  • Maintain coolant level within 13 mm (0.5 inch) below filler pipe

Full service-parts list: Perkins 1106C-70TA →, Perkins 1106D-70TA →

Source: Perkins operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Perkins repair guides →