Perkins — Battery Electrolyte Level - Check
Maintenance · Batteries
From a Perkins operator's manual covering: 1106C-70TA, 1106D-70TA, SEBU8731. Check it applies to your exact model before use.
Applies to: Perkins 1106C-70TA, Perkins 1106D-70TA
Before you start
- All lead-acid batteries contain sulfuric acid which can burn the skin and clothing
- Always wear a face shield and protective clothing
Parts for this job
Part numbers from the service-parts lists for Perkins 1106C-70TA, Perkins 1106D-70TA. Verify against your serial number before ordering; some links are affiliate links.
Procedure
- Remove the filler caps; maintain electrolyte level to the FULL mark.
- Use distilled water; if unavailable use clean water low in minerals.
- Check the condition of the electrolyte with the 245-5829 Coolant Battery Tester Refractometer.
- Clean the battery case with baking soda solution or ammonium hydroxide; rinse with clean water.
- Clean terminals and cable clamps with fine grade sandpaper.
- Coat clamps and terminals with 5N-5561 Silicone Lubricant, petroleum jelly or MPGM.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Full service-parts list: Perkins 1106C-70TA →, Perkins 1106D-70TA →
Source: Perkins operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.