Home›Repair guides›Perkins›Engine Air Cleaner Element (Dual Element) - Inspect/Clean/Replace

Perkins 1106C-70TA / 1106D-70TA — Engine Air Cleaner Element (Dual Element) - Inspect/Clean/Replace

Maintenance

For the Perkins 1106C-70TA / 1106D-70TA, from the Perkins owner's manual.

Applies to: Perkins 1106C-70TA, Perkins 1106D-70TA

Before you start

  • Never run engine without an air cleaner element installed.
  • Never service air cleaner element with engine running.

Parts for this job

Part numbers from the service-parts lists for Perkins 1106C-70TA, Perkins 1106D-70TA. Verify against your serial number before ordering; some links are affiliate links.

Procedure

  1. Remove cover. Remove primary air cleaner element.
  2. Secondary air cleaner element should be removed and discarded every three cleanings of primary.
  3. Cover air inlet with tape to keep out dirt.
  4. Clean inside of air cleaner cover and body with clean, dry cloth.
  5. Remove tape from air inlet. Install secondary air cleaner element. Install new or cleaned primary element.
  6. Install air cleaner cover.
  7. Reset air cleaner service indicator.
  8. Clean primary element with pressurized air (max 207 kPa) or vacuum cleaning. Do not tap or strike. Do not wash.
  9. Inspect primary element with 60 W blue light for tears/holes. Discard damaged elements.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Maximum air pressure 207 kPa (30 psi)

Full service-parts list: Perkins 1106C-70TA →, Perkins 1106D-70TA →

Source: Perkins owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Perkins repair guides →