Home›Repair guides›Perkins›Battery or Battery Cable - Disconnect

Perkins 1106C-70TA / 1106D-70TA — Battery or Battery Cable - Disconnect

Maintenance

For the Perkins 1106C-70TA / 1106D-70TA, from the Perkins owner's manual.

Applies to: Perkins 1106C-70TA, Perkins 1106D-70TA

Parts for this job

  • 102330138 Battery — Perkins 1106D-70TA Amazon eBay

Part numbers from the service-parts lists for Perkins 1106C-70TA, Perkins 1106D-70TA. Verify against your serial number before ordering; some links are affiliate links.

Procedure

  1. Turn start switch to OFF. Turn ignition switch to OFF and remove key and all electrical loads.
  2. Disconnect negative battery terminal. Ensure cable cannot contact terminal. When four 12 volt batteries are involved, two negative connections must be disconnected.
  3. Remove positive connection.
  4. Clean all disconnected connections and battery terminals.
  5. Use fine grade sandpaper to clean terminals and cable clamps until bright. Do not remove material excessively. Coat with silicone lubricant or petroleum jelly.
  6. Tape cable connections to help prevent accidental starting.
  7. Proceed with necessary system repairs.
  8. To connect battery, connect positive connection before negative connection.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Perkins 1106C-70TA →, Perkins 1106D-70TA →

Source: Perkins owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.