Home›Repair guides›Perkins›Aftercooler Core - Clean/Test

Perkins 1106C-70TA / 1106D-70TA — Aftercooler Core - Clean/Test

Maintenance

For the Perkins 1106C-70TA / 1106D-70TA, from the Perkins owner's manual.

Applies to: Perkins 1106C-70TA, Perkins 1106D-70TA

Before you start

  • Personal injury can result from air pressure. Wear protective face shield and clothing.

Procedure

  1. Remove core. Refer to OEM information for correct procedure.
  2. Turn aftercooler core upside-down to remove debris.
  3. Use pressurized air to remove loose debris. Direct air opposite to fan airflow. Hold nozzle approximately 6 mm from fins. Move parallel with tubes.
  4. Pressurized water may be used. Maximum water pressure less than 275 kPa. Use to soften mud. Clean core from both sides.
  5. Back flush core with suitable cleaner.
  6. Clean core with steam to remove residue. Flush fins of aftercooler core.
  7. Wash core with hot, soapy water. Rinse core thoroughly with clean water.
  8. Dry core with compressed air. Direct air in reverse direction of normal flow.
  9. Inspect core for cleanliness. Pressure test core. Repair if necessary.
  10. Install core. Refer to OEM information.
  11. Start engine and accelerate to high idle. Stop engine. Use light bulb behind core to inspect cleanliness. Repeat if necessary.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Air pressure maximum 205 kPa (30 psi)
  • Water pressure maximum 275 kPa (40 psi)

Full service-parts list: Perkins 1106C-70TA →, Perkins 1106D-70TA →

Source: Perkins owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.