Procedure

  1. Change engine oil and filter as recommended.
  2. Run engine up to at least 140°F from a small clean source of fuel dosed with fuel system stabilizer/conditioner.
  3. Completely drain, flush and fill cooling system with pre-mixed 50/50 ethylene-glycol coolant.
  4. Loosen alternator drive belt.
  5. Seal off intake and exhaust openings with plastic bags and duct tape.
  6. Cover entire engine in a large plastic bag with desiccant packs.
  7. Store engine inside a building, preferably climate controlled.

Specs & values

  • For storage longer than 3 months
  • Run engine up to at least 140°F

Full service-parts list: Northern Lights M20CRW3 →, Northern Lights M844DW3 →, Northern Lights M844LW3 →, Northern Lights M844W3 →