Northern Lights — Winterizing / Out-of-Service (SP-20)
Maintenance · Generator set
From a Northern Lights owner's manual covering: 844DW3, 844LW3, M20CRW3, M844DW3, M844LW3, M844W3. Check it applies to your exact model before use.
Applies to: Northern Lights M20CRW3, Northern Lights M844DW3, Northern Lights M844LW3, Northern Lights M844W3, Northern Lights 844L engine
Procedure
- Change engine oil and filter as recommended.
- Run engine up to at least 140°F from a small clean source of fuel dosed with fuel system stabilizer/conditioner.
- Completely drain, flush and fill cooling system with pre-mixed 50/50 ethylene-glycol coolant.
- Loosen alternator drive belt.
- Seal off intake and exhaust openings with plastic bags and duct tape.
- Cover entire engine in a large plastic bag with desiccant packs.
- Store engine inside a building, preferably climate controlled.
Specs & values
- For storage longer than 3 months
- Run engine up to at least 140°F
Full service-parts list: Northern Lights M20CRW3 →, Northern Lights M844DW3 →, Northern Lights M844LW3 →, Northern Lights M844W3 →
Source: Northern Lights owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.