Home›Repair guides›Northern Lights›Winterize or store generator set

Northern Lights — Winterize or store generator set

Maintenance

From a Northern Lights operator's manual covering: M30, M38C3, M38C3F, M40C3F, M944. Check it applies to your exact model before use.

Applies to: Northern Lights M30, Northern Lights M38C3, Northern Lights M38C3F, Northern Lights M40C3F, Northern Lights M944

Procedure

  1. Change engine oil and filter.
  2. Run engine no load 1 to 2 minutes to circulate clean oil.
  3. Drain, flush, and fill cooling system with pre-mixed 50/50 ethylene-glycol coolant.
  4. Loosen alternator drive belt.
  5. Seal intake and exhaust openings with heavy plastic bags and duct tape.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • For storage longer than 3 months

Full service-parts list: Northern Lights M30 →, Northern Lights M38C3 →, Northern Lights M38C3F →, Northern Lights M40C3F →, Northern Lights M944 →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.