Home›Repair guides›Northern Lights›Valve clearance adjustment (SP6)

Northern Lights — Valve clearance adjustment (SP6)

Adjustments · Valve train

From a Northern Lights operator's manual covering: M16, M20, M20C, M844, M844L, ML844, ML844L, NL844. Check it applies to your exact model before use.

Applies to: Northern Lights M20C, Northern Lights M844, Northern Lights M844L, Northern Lights ML844, Northern Lights ML844L, Northern Lights NL844, Northern Lights 844 / 844L engine, Northern Lights 844L engine

Procedure

  1. Readjust valve clearance after first 50 hours of operation and every 600 hours thereafter.
  2. Valve adjustments should be done after the cylinder head bolts have been retightened.
  3. Engine should be cold and NOT running.
  4. Turn engine by hand until inlet valve starts to open and exhaust valve starts to close.
  5. Turn crankshaft one more full turn and adjust clearance on both valves for this cylinder.
  6. Loosen lock nut and adjust clearance between rocker arm and valve guide with adjustment screw.
  7. Repeat for each cylinder; each set of valves must be adjusted individually.
  8. Replace rocker arm cover.

Specs & values

  • Clearance on both intake and exhaust valves should be 0.008 in. (0.2 mm)

Full service-parts list: Northern Lights M20C →, Northern Lights M844 →, Northern Lights M844L →, Northern Lights ML844 →, Northern Lights ML844L →, Northern Lights NL844 →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.