Home›Repair guides›Northern Lights›Starting Northern Lights set

Northern Lights — Starting Northern Lights set

Operation · Engine and generator control panel

From a Northern Lights operator's manual covering: 753, L753, L843, L854, M354-G, M753, M843, M854, M892. Check it applies to your exact model before use.

Applies to: Northern Lights 753, Northern Lights M753, Northern Lights M843, Northern Lights 854A engine, Northern Lights 854B engine

Before you start

  • Holding preheat switch up too long can burn out the glow plugs.

Procedure

  1. Turn engine control switch to the run position.
  2. Push up on shutdown bypass-preheat switch for approximately 10 to 20 seconds.
  3. Turn engine control switch to start while pushing up on shutdown bypass-preheat switch.
  4. Release both switches as soon as engine starts.
  5. Check all instruments.

Specs & values

  • Preheat: approximately 10 to 20 seconds.

Full service-parts list: Northern Lights 753 →, Northern Lights M753 →, Northern Lights M843 →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.