Northern Lights — Starting

Operation · engine

From a Northern Lights operator's manual covering: NL378, NL378x, NL484, NL488x, NL498x. Check it applies to your exact model before use.

Applies to: Northern Lights NL378, Northern Lights NL378x, Northern Lights NL484, Northern Lights NL488x, Northern Lights NL498x

Before you start

  • Holding the switch too long can burn out the heater elements.

Procedure

  1. Hold the Shutdown Bypass-Preheat switch in the ON position for 10 to 20 seconds before starting a cold engine.
  2. While holding the Shutdown Bypass-Preheat switch ON, push the Engine Control switch to START.
  3. As soon as the engine starts, release both switches.
  4. Do not crank the starter for more than 20 seconds consecutively.
  5. If engine fails to start, be sure it has stopped completely before re-engaging.

Specs & values

  • 10 to 20 seconds preheat
  • 20 seconds maximum cranking

Full service-parts list: Northern Lights NL378 →, Northern Lights NL378x →, Northern Lights NL484 →, Northern Lights NL488x →, Northern Lights NL498x →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.