Procedure
- If not used for more than 3 months, change engine oil and filter.
- Run engine up to at least 140°F from a clean fuel source dosed with fuel system stabilizer/conditioner.
- Completely drain, flush and fill the cooling system with pre-mixed 50/50 conventional ethylene-glycol heavy-duty diesel engine coolant.
- Loosen alternator drive belt.
- Seal off intake and exhaust openings with heavy plastic bags and duct tape.
- Cover entire engine in large plastic bag, tape closed at bottom, place moisture absorbing desiccant packs inside.
- Store engine inside a building (preferably climate controlled).
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Run engine to at least 140°F
- Storage for more than 3 months
Full service-parts list: Northern Lights M20CRW3 →, Northern Lights M844DW3 →, Northern Lights M844LW3 →, Northern Lights M844W3 →