Home›Repair guides›Northern Lights›SP-17 Raw Water Pump Impeller Replacement

Northern Lights — SP-17 Raw Water Pump Impeller Replacement

Maintenance

From a Northern Lights operator's manual covering: M30, M38C3, M38C3F, M40C3F, M944. Check it applies to your exact model before use.

Applies to: Northern Lights M30, Northern Lights M38C3, Northern Lights M38C3F, Northern Lights M40C3F, Northern Lights M944

Before you start

  • Place protection under the screwdrivers so the pump housing is not damaged.

Procedure

  1. Change the raw water pump impeller every 500 hours, or as needed.
  2. Remove the pump cover.
  3. Pry out the impeller using needle-nose pliers or two screwdrivers, protecting the pump housing.
  4. Be sure to remove all pieces of the failed impeller and clean inside of housing.
  5. Press in new impeller and place sealing plug in the outer end of the impeller center.
  6. Keep an extra impeller and cover gasket in reserve on board.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Change impeller every 500 hours

Full service-parts list: Northern Lights M30 →, Northern Lights M38C3 →, Northern Lights M38C3F →, Northern Lights M40C3F →, Northern Lights M944 →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Northern Lights repair guides →