Home›Repair guides›Northern Lights›Winterizing / Out-of-Service

Northern Lights NL382W — Winterizing / Out-of-Service

Maintenance · Generator set

For the Northern Lights NL382W, from the Northern Lights operator's manual.

Applies to: Northern Lights NL382W

Procedure

  1. Drain and flush radiator/cooling system; leave dry or refill with antifreeze-water mixture.
  2. Fill fuel tank or add biocide as per manufacturer instructions.
  3. Seal air cleaner inlet, exhaust opening, crankcase breather pipe, and fuel tank vent with plastic bags and tape.
  4. Change crankcase oil and filter.
  5. Loosen alternator belt.
  6. Disconnect and clean battery; remove to warm storage if possible.
  7. Clean outside; paint scratches; apply corrosion preventative.
  8. Store in dry protected place; cover if stored outside.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Northern Lights NL382W →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.