Northern Lights M864 — Starting

Operation · Generator set

For the Northern Lights M864, from the Northern Lights owner's manual.

Applies to: Northern Lights M864

Before you start

  • Holding the Shutdown Bypass switch too long can burn out the glow plugs.
  • Excessive cranking on sets with a water lift muffler can cause engine damage.

Procedure

  1. Hold Shutdown Bypass switch ON for 10-20 seconds before starting.
  2. While holding Shutdown Bypass ON, push Engine Control switch to START.
  3. As soon as engine starts, release both switches.
  4. Do not crank starter more than 20 seconds consecutively.
  5. If engine fails to start, ensure it has stopped completely before re-engaging.
  6. If no start after 3 consecutive 20-second cranks, remove impeller from seawater pump, restart, then shut off immediately and reinstall impeller.

Specs & values

  • Shutdown Bypass ON for 10-20 seconds
  • Max cranking 20 seconds consecutively

Full service-parts list: Northern Lights M864 →

Source: Northern Lights owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.