Northern Lights M864 / OM864W — Zinc Electrode Service
Maintenance · Heat exchanger zinc electrode
For the Northern Lights M864 / OM864W, from the Northern Lights operator's manual.
Applies to: Northern Lights M864
Procedure
- Check the zinc electrode every 200 hours; more often in warm saltwater or where electrolysis is a known problem.
- Remove the zinc holder from the bottom of the exchanger; this drains raw water from the exchanger.
- Scrape or steel brush the zinc electrode clean.
- If more than 50% of the electrode is corroded away, replace it with a new zinc; the electrode screws out of the holder.
- Reinstall the zinc holders with clean threads; do not use thread sealant.
- Refill the cooling system, start the engine and check for leaks.
Tools required
- Steel brush Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Replace when more than 50% corroded away
Full service-parts list: Northern Lights M864 →
Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.