Home›Repair guides›Northern Lights›Winterizing/out-of-service

Northern Lights M673 / OM673 — Winterizing/out-of-service

Maintenance · Generator set

For the Northern Lights M673 / OM673, from the Northern Lights operator's manual.

Applies to: Northern Lights M673, Northern Lights OM673

Before you start

  • Shut off seacocks before opening drain cocks if vessel is in water

Procedure

  1. Drain fresh water and seawater cooling systems completely.
  2. Drain water supply lines and wet exhaust line.
  3. Loosen seawater pump cover and drain pump.
  4. Change crankcase oil and filter.
  5. Loosen alternator belt.
  6. Disconnect and clean battery; remove to warm storage if possible.
  7. Clean outside; paint scratches; apply corrosion preventative.
  8. Fill fuel tank or add biocide.

Full service-parts list: Northern Lights M673 →, Northern Lights OM673 →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.