Northern Lights M673 / NL673 — Retrofit Procedure
Repair & overhaul · Voltage regulator (DS-71-2 to DST-61)
For the Northern Lights M673 / NL673, from the Northern Lights service manual.
Applies to: Northern Lights M673, Northern Lights NL673
Procedure
- Disconnect AVR connector and yellow and brown leads from the small terminal block.
- Remove four screws that mount the old regulator and remove the regulator.
- Install the adaptor mounting plate in the junction box with the 4 short screws and lock washers.
- Install the DST-61 regulator with the 4 long screws and lock washers.
- Cut the number 4 conductor from the generator and crimp on the two lugs. Tug test the crimps.
- Assemble the fuse into the fuse holder and connect the two new crimp lugs to the fuse holder terminals. Secure with tie wraps.
- Reconnect AVR connector and yellow and brown leads to the small terminal block.
Specs & values
Full service-parts list: Northern Lights M673 →, Northern Lights NL673 →