Before you start

  • Close sea-cock before opening drain cocks.

Procedure

  1. Change crankcase oil and filter; fill with rust preventative oil.
  2. Make 1:1 rust preventative oil and fuel mixture; fill fuel tank.
  3. Run engine unloaded 5 to 10 minutes; drain rust preventative oil and fuel.
  4. Drain fresh water and seawater cooling systems completely.
  5. Drain water supply and wet exhaust lines; cover intake and exhaust ports.
  6. Loosen seawater pump cover and alternator belt.
  7. Disconnect and clean battery; store in cool dry place.
  8. Cover engine and exposed metal surfaces.