Northern Lights M38CR2 / M944 — Starting

Operation · Generator set

For the Northern Lights M38CR2 / M944, from the Northern Lights operator's manual.

Applies to: Northern Lights M38CR2, Northern Lights M944

Before you start

  • Excessive cranking with water lift muffler can cause engine damage.

Procedure

  1. Hold Shutdown Bypass switch in ON position.
  2. Push Engine Control switch to START while holding bypass.
  3. Release start switch when engine starts; hold bypass five seconds more.
  4. Do not crank starter more than 10 seconds consecutively.
  5. If engine does not start after three 10-second cranks, remove seawater pump impeller.
  6. Reinstall impeller after engine starts and check exhaust water flow.

Full service-parts list: Northern Lights M38CR2 →, Northern Lights M944 →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Northern Lights repair guides →