From a Northern Lights operator's manual covering: M40C3, M944, OM944T3. Check it applies to your exact model before use.

Applies to: Northern Lights M40C3, Northern Lights M944

Before you start

  • Scaling removal with 50/50 muriatic acid and water must be performed only by a qualified technician with the heat exchanger removed.

Procedure

  1. Clean the heat exchanger core as needed.
  2. Drain the expansion tank and heat exchanger.
  3. Remove the heat exchanger end covers.
  4. Clean inside the exchanger core tubes using a metal rod; flush, inspect, and clean again if necessary.
  5. Reassemble the heat exchanger, fill the cooling system, start engine and check for leaks.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Northern Lights M40C3 →, Northern Lights M944 →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.