Home›Repair guides›MQ Power›Generator Start-Up (Manual)

MQ Power DCA-220SSV / DCA-220SSVU — Generator Start-Up (Manual)

Operation · Generator set

For the MQ Power DCA-220SSV / DCA-220SSVU, from the MQ Power operator's manual.

Applies to: MQ Power DCA-220SSV, MQ Power DCA-220SSVU, Volvo Penta TAD520GE engine, Volvo Penta TAD741GE engine

Before you start

  • Engine exhaust contains harmful emissions; always have adequate ventilation.

Procedure

  1. Place main, GFCI and auxiliary circuit breakers in OFF position.
  2. Make sure voltage change-over board is configured for desired output voltage.
  3. Connect load to receptacles or output terminal lugs.
  4. Remove plastic output terminal cover and tighten terminal nuts securely.
  5. Close all engine enclosure doors.
  6. In cold weather, press and hold pre-heat button at least 50 seconds.
  7. Place MPEC control switch in MANUAL position to start engine.
  8. Run engine 1-2 minutes; listen for abnormal noises; verify Engine Running LED is ON.

Specs & values

  • Pre-heat button held at least 50 seconds in cold weather

Full service-parts list: MQ Power DCA-220SSV →, MQ Power DCA-220SSVU →

Source: MQ Power operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.