Home›Repair guides›MQ Power›Generator Grounding

MQ Power DCA-220SSV / DCA-220SSVU — Generator Grounding

Installation · Generator earth ground

For the MQ Power DCA-220SSV / DCA-220SSVU, from the MQ Power operator's manual.

Applies to: MQ Power DCA-220SSV, MQ Power DCA-220SSVU, Volvo Penta TAD520GE engine, Volvo Penta TAD741GE engine

Before you start

  • Consult a licensed electrician before connecting generator to a building's electrical system.

Procedure

  1. Use copper 10 AWG (5.3 mm2) or larger ground wire.
  2. Use aluminum 8 AWG (8.4 mm2) or larger ground wire.
  3. Connect ground cable between lock washer and nut on generator.
  4. Tighten nut fully and connect other end to earth ground.
  5. Bury earth ground rod minimum 8 ft into ground (NEC 250-52(c)).

Specs & values

  • Copper 10 AWG (5.3 mm2) or larger
  • Aluminum 8 AWG (8.4 mm2) or larger
  • Ground rod buried minimum 8 ft

Full service-parts list: MQ Power DCA-220SSV →, MQ Power DCA-220SSVU →

Source: MQ Power operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.