For the Magnum MTT25 / MTT25CAN, from the Magnum operator's manual.

Applies to: Magnum MTT25, Magnum MTT25CAN, Isuzu 4LE1NYGV-01 / 4LE1NYGV-03E engine, Isuzu 4LE1NYGV-03G / 4LE1NYGV-03E engine

Before you start

  • If the voltage is increased or decreased too fast or too slow, the unit will automatically shut down.

Procedure

  1. Upon startup the Running screen displays 'V Detect' and counts down from 45 seconds to zero.
  2. The controller records the generator nominal output voltage and compares it to the voltage selector switch set point.
  3. If the recorded nominal voltage differs from the selector switch set point by 10% or more, the controller shuts the generator down.
  4. Adjust output voltage with the fine voltage adjustment screw (rheostat) below the Control Power switch within the 45 second delay.
  5. Check 'L1N' or 'L12' voltage on the Generator screen and turn the screw until it matches the selector switch rating within 10%.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • V Detect delay 45 seconds
  • Generator output must be within +/- 10% of selector switch rating

Source: Magnum operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.