Home›Repair guides›Magnum›Auto Exercise Timer

Magnum MTT25 / MTT25CAN — Auto Exercise Timer

Operation · Magnum Digital Controller (MDC)

For the Magnum MTT25 / MTT25CAN, from the Magnum operator's manual.

Applies to: Magnum MTT25, Magnum MTT25CAN, Isuzu 4LE1NYGV-01 / 4LE1NYGV-03E engine, Isuzu 4LE1NYGV-03G / 4LE1NYGV-03E engine

Before you start

  • The controller must be in Auto mode to run at the programmed time. Use a trickle battery charger or solarizer to prevent draining the battery while in Auto mode.

Procedure

  1. Press PAGE SELECT until 'Password' appears at the top of the screen.
  2. Press down until 'Date/Time' is selected and press ENTER.
  3. Press down until 'Timer1 Repeat' is selected and press ENTER; choose the day(s) the unit should run and press ENTER.
  4. Press down until 'Timer1 ON Time' is selected; adjust the start time and press ENTER.
  5. Press down until 'Timer1Duration' is selected; adjust the run duration and press ENTER.
  6. Press PAGE SELECT three times to return to the Main menu.
  7. Press AUTO to switch modes to automatic.

Source: Magnum operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.