Magnum MTP4000S — Pump Lubrication
Maintenance · Mechanical seal and bearings
For the Magnum MTP4000S, from the Magnum operator's manual.
Applies to: John Deere PE4024TF281 engine
Before you start
- Over-filling with oil can result in premature failure of bearings
Procedure
- Prior to starting the pump, remove the seal vent plug and fill the seal cavity with approximately one quart (33 oz) of ISO VG 32 turbine oil.
- Fill the seal cavity so the oil level is halfway in the level sight gauge.
- Maintain the bearing housing oil at the middle of the sight gauge.
- Use an ISO viscosity grade 32 turbine oil and fill through the air vent hole at the top right of the bearing frame.
Specs & values
- Mechanical seal cavity approximately one quart (33 oz) of ISO VG 32 turbine oil
- Drain and refill bearing housing at least once every 12 months
Source: Magnum operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.