Home›Repair guides›Magnum›Checking Generator Drive Plate Torque

Magnum MMG330 / MMG330 Super Start — Checking Generator Drive Plate Torque

Maintenance

For the Magnum MMG330 / MMG330 Super Start, from the Magnum owner's manual.

Applies to: Magnum MMG330, Magnum MMG330 Super Start, John Deere PE609HFG95 engine

Procedure

  1. Disconnect the engine starting battery
  2. Remove the generator fan guard
  3. Torque each of the drive plate bolts to the specification (MMG330: 33 ft-lb / 45 Nm)
  4. Reinstall the generator fan guard and reconnect the battery

Specs & values

  • MMG330: 33 ft-lb (45 Nm)

Source: Magnum owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.