Magnum MLT4000S — Shutting Down
Operation · Light tower
For the Magnum MLT4000S, from the Magnum operator's manual.
Applies to: Magnum MLT4000S, Generac GN-220 engine
Before you start
- Always transport the unit with BOTH CYLINDER VALVES CLOSED. Not doing so increases the risk of fire or explosion due to damage from road debris or an accident.
Procedure
- Set the Gen Power switch to the Off position.
- Set the Timer Control mode to Off.
- Close the cylinder valves on BOTH LP tanks.
Full service-parts list: Magnum MLT4000S →
Source: Magnum operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.