Kohler — Voltage regulator operation check

Testing & diagnosis · Electric system / voltage regulator

From a Kohler service manual covering: KD 626-3, KD 626-3 B2 NR, KD 626-3 EPA, KD 626-3 NR. Check it applies to your exact model before use.

Applies to: Kohler KD 626-3, Kohler KD 626/3 engine

Before you start

  • When the engine is running do not disconnect battery cables or remove the key from the control panel
  • Keep regulator away from heat sources (above 75°C may damage it)
  • No electric welding on engine or application

Procedure

  1. Check that connections correspond to the layout.
  2. Disconnect the terminal from the battery positive pole.
  3. Connect a d.c. voltmeter between the two battery poles.
  4. Fit an ammeter between the positive pole and the corresponding cable 1 terminal.
  5. Start a couple of times until battery voltage drops below 13 V.
  6. When battery voltage reaches 14,5 V the ammeter current suddenly drops to almost zero.
  7. Replace regulator if recharge current is zero with voltage below 14 V.

Tools required

  • d.c. voltmeter Amazon
  • Ammeter (14 or 21 A, withstand 400 ÷ 450 A) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Regulator 12 V, max. current 26 A
  • When battery voltage reaches 14,5 V current drops to almost zero

Full service-parts list: Kohler KD 626-3 →