Procedure
- Press OFF; disconnect engine starting battery, negative lead first.
- Disconnect utility power to generator set and power to the ATS.
- Connect ohmmeter or test lamp across terminals NO and C of switch LSN or SN.
- Manually operate the transfer switch; verify NO contact opens and closes.
- Repeat for the NC contact; it should open when pressed, close when released.
- Verify there is no continuity between the NO and NC terminals.
- Repeat steps for switch LSE or SE.