Home›Repair guides›Kohler›Stop setting

Kohler — Stop setting

Adjustments · Injection pump control rod

From a Kohler service manual covering: KD 626-3, KD 626-3 B2 NR, KD 626-3 EPA, KD 626-3 NR. Check it applies to your exact model before use.

Applies to: Kohler KD 626-3, Kohler KD 626/3 engine

Procedure

  1. Remove fuel feeding pump and cover.
  2. Loosen both bolts fixing plate A.
  3. Push injection pump B control rod to the right and keep it in this position.
  4. Push plate A to the right until it touches rod B and stop.
  5. Release rod B and push plate A to the right so that rod B has a stroke of 1 mm.
  6. Tighten both bolts.

Specs & values

  • Rod B stroke 1 mm

Full service-parts list: Kohler KD 626-3 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →