Kohler — Static Timing Method

Adjustments · Ignition system

From a Kohler service manual covering: KT17, KT17 Series II, KT19 Series II, KT21, Kt19. Check it applies to your exact model before use.

Applies to: Kohler Kt19

Before you start

  • Make sure ignition switch is off and spark plug leads disconnected to prevent unintentional starting.

Procedure

  1. Make sure ignition switch is off and disconnect spark plug leads.
  2. Remove breaker point cover; connect ohmmeter or continuity tester from breaker point terminal to ground.
  3. Rotate engine by hand clockwise (viewed from flywheel end) until points just begin to break.
  4. When points just break, the S mark on flywheel should be directly opposite the roll pin in the #1 cylinder barrel.
  5. If S is above or below the roll pin, adjust point gap until S mark is opposite the roll pin.
  6. If no meter is available, set gap to .020" fully open; gap may vary .017"-.023" for smoothest running.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Point gap .020" fully open
  • .017"-.023" range
  • S mark 23 degrees BTDC

Full service-parts list: Kohler Kt19 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.