Kohler — Static Timing Method
Adjustments · Ignition system
From a Kohler service manual covering: KT17, KT17 Series II, KT19 Series II, KT21, Kt19. Check it applies to your exact model before use.
Applies to: Kohler Kt19
Before you start
- Make sure ignition switch is off and spark plug leads disconnected to prevent unintentional starting.
Procedure
- Make sure ignition switch is off and disconnect spark plug leads.
- Remove breaker point cover; connect ohmmeter or continuity tester from breaker point terminal to ground.
- Rotate engine by hand clockwise (viewed from flywheel end) until points just begin to break.
- When points just break, the S mark on flywheel should be directly opposite the roll pin in the #1 cylinder barrel.
- If S is above or below the roll pin, adjust point gap until S mark is opposite the roll pin.
- If no meter is available, set gap to .020" fully open; gap may vary .017"-.023" for smoothest running.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Point gap .020" fully open
- .017"-.023" range
- S mark 23 degrees BTDC
Full service-parts list: Kohler Kt19 →
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.