Procedure

  1. Disconnect the 10-pin cable at the P8 connector on the circuit board.
  2. Disconnect the 8-pin cable at the P10 connector on the circuit board.
  3. Remove the existing three nuts and lock washers attaching the gauge drive circuit board to the indicator panel circuit board.
  4. Remove existing 24-position ribbon cable 336428; it will not be reused.
  5. Attach the end connector (nearest the inline connector) of new ribbon cable GM32632 to indicator panel circuit board P4.
  6. Attach the other end connector of ribbon cable GM32632 to main circuit board P3.

Specs & values

  • Replacement 24-position ribbon cable: GM32632
  • Removed ribbon cable: 336428

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.