Kohler — Procedures to be carried out before starting the engine after storage
Maintenance
From a Kohler service manual covering: KD 626-3, KD 626-3 B2 NR, KD 626-3 EPA, KD 626-3 NR. Check it applies to your exact model before use.
Applies to: Kohler KD 626-3, Kohler KD 626/3 engine
Procedure
- Remove all protections and coverings.
- Remove the rust preventer from the external part of the engine with solvent or degreaser.
- Tension the blower timing belt.
- Disassemble the injectors and introduce motor oil on the piston crown (no more than 2 cc for every cylinder).
- Remove valve covers, spray motor oil on the valves and turn the crankshaft manually for a few revolutions.
- Start the engine and heat it for about 10 minutes.
- Remove the drain plug and let the protective oil flow completely.
- Reinsert the drain plug.
- Refill motor oil to the upper level of the rod using the recommended oil.
Specs & values
- No more than 2 cc of oil for every cylinder
Full service-parts list: Kohler KD 626-3 →
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.