From a Kohler service manual covering: 100 ROZ, 100 RZ, 150 ROZ, 150 RZ, 20 ROZ, 20 RZ, 50 RZ, 50ROZ. Check it applies to your exact model before use.

Applies to: Kohler 100 RZ, Kohler 20 RZ, Kohler 50ROZ

Before you start

  • Unit starts without notice; turn Master Switch off and remove battery cables.
  • Electrical shock from battery; remove jewelry.
  • Hot piping; allow unit to cool.
  • Flash fire; no smoking or flames near fuel.

Procedure

  1. Disconnect starting batteries, negative lead first; remove from work area.
  2. Disconnect AC accessories: battery charger, block heater, fuel transfer pump.
  3. Shut off fuel supply and drain fuel into proper containers.
  4. Ventilate work area to clear fumes.
  5. Disconnect fuel, cooling, and exhaust systems as necessary to tilt generator.
  6. Disconnect output leads or load circuit cables at generator.
  7. Check generator weight on nameplate; verify lifting equipment rated.

Tools required