Before you start
- Never manually operate the transfer switch when the power is connected. Disconnect both power sources before manually operating the switch.
Procedure
- 100-200 amp switches have an attached handle; 400 amp switches: slide the detachable handle or a wrench over the shaft.
- Move the handle up to place the transfer switch in the Normal Source position, or down for the Emergency Source position.
- 400 amp switches: remove the detachable handle or wrench.