Home›Repair guides›Kohler›Ignition Timing - Static Timing (Method 1)

Kohler — Ignition Timing - Static Timing (Method 1)

Adjustments · ignition system

From a Kohler service manual covering: KT17, KT17 Series II, KT19 Series II, KT21, Kt19. Check it applies to your exact model before use.

Applies to: Kohler Kt19

Procedure

  1. Make sure ignition switch is off. Completely disconnect spark plug leads from plugs.
  2. Remove breaker point cover, connect an ohmmeter or continuity tester from breaker point terminal to ground.
  3. Rotate the engine by hand in direction of normal rotation (clockwise viewed from flywheel end).
  4. When points are just breaking, the S mark on the flywheel should be directly opposite the roll pin in the #1 cylinder barrel.
  5. If S is above or below roll pin, adjust point gap in or out until S mark is directly opposite the roll pin.
  6. If no ohmmeter, measure gap with feeler gauge; gap should be .020 inch fully open.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Gap .020 inch fully open; maximum gap may vary .017-.023 inch

Full service-parts list: Kohler Kt19 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.