Kohler — Ignition Timing - Static Timing (Method 1)
Adjustments · ignition system
From a Kohler service manual covering: KT17, KT17 Series II, KT19 Series II, KT21, Kt19. Check it applies to your exact model before use.
Applies to: Kohler Kt19
Procedure
- Make sure ignition switch is off. Completely disconnect spark plug leads from plugs.
- Remove breaker point cover, connect an ohmmeter or continuity tester from breaker point terminal to ground.
- Rotate the engine by hand in direction of normal rotation (clockwise viewed from flywheel end).
- When points are just breaking, the S mark on the flywheel should be directly opposite the roll pin in the #1 cylinder barrel.
- If S is above or below roll pin, adjust point gap in or out until S mark is directly opposite the roll pin.
- If no ohmmeter, measure gap with feeler gauge; gap should be .020 inch fully open.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Gap .020 inch fully open; maximum gap may vary .017-.023 inch
Full service-parts list: Kohler Kt19 →
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.