Home›Repair guides›Kohler›Governor System Operation Test

Kohler — Governor System Operation Test

Testing & diagnosis · Governor/stepper motor

From a Kohler service manual covering: 14/20RCA/RCAL, 14RCA, 20RCA, 26RCA, 26RCA/RCAL. Check it applies to your exact model before use.

Applies to: Kohler 14RCA, Kohler 20RCA, Kohler 26RCA, Kohler CH740 / CH1000 / CH1006 engine

Before you start

  • Hazardous voltage. Moving parts.

Procedure

  1. Verify carburetor throttle linkage is connected to stepper motor.
  2. Check for broken or loose wiring or plug connections.
  3. Check stepper motor operation at startup (open then closed position).
  4. Open circuit breaker, disconnect starting battery, shut off fuel supply.
  5. Disconnect stepper motor plug P6 to access terminals.
  6. Check coil resistance across pins 2-3 and pins 1-4.
  7. Inspect linkage and bushings; replace as necessary.
  8. Disconnect linkage; verify free full range of motion.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Resistance per half coil 38.5 ohms

Full service-parts list: Kohler 14RCA →, Kohler 20RCA →, Kohler 26RCA →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.