Home›Repair guides›Kohler›Governor Adjustment

Kohler — Governor Adjustment

Adjustments · Electronic governor

From a Kohler service manual covering: 10C, 10CC, 10CFC, 10CFZ, 12C, 12CFC, 12CFZ, 40CZ, CZ/12-Lead. Check it applies to your exact model before use.

Applies to: Kohler 10C, Kohler 12C, Ford VSG-411 (10 kW) / VSG-413 (12 kW) engine

Before you start

  • Do not tamper with -2.5 Hz/Freq terminals during governor adjustment.

Procedure

  1. Verify swivel on actuator arm fully threaded and secured.
  2. Adjust throttle rod to approx. 3-7/8 in. (98 mm) between ball joints.
  3. For 50 Hz install jumper across 50/60 Hz terminals; for 60 Hz no jumper.
  4. Install jumper across Gain Change terminals; set gain pot to 3.
  5. Start set, apply full load; adjust gain until actuator stable.
  6. Check battery voltage at governor board + and - terminals: at least 11 V DC.
  7. Check AC voltage at Gen Volt terminal: at least 90 V AC.
  8. If needed, lengthen actuator rod linkage one turn.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Throttle rod 3-7/8 in. (98 mm)
  • Battery at least 11 V DC
  • AC at least 90 V AC
  • Natural gas pressure at least 5 in. water column

Full service-parts list: Kohler 12C →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.