Home›Repair guides›Kohler›ECU Reset Procedure (non-ETB)

Kohler ECV940 / ECV980 — ECU Reset Procedure (non-ETB)

Testing & diagnosis · Electronic Control Unit (ECU)

For the Kohler ECV940 / ECV980, from the Kohler service manual.

Applies to: Kohler ECV940, Kohler ECV980

Before you start

  • This system will NOT reset when battery is disconnected.

Procedure

  1. Turn key/ignition OFF.
  2. Install Red wire jumper from Kohler EFI service kit to service port (connect white to black wire in 4 way diagnostic port).
  3. Turn key ON then OFF, count 10 seconds.
  4. Turn key ON then OFF, count to 10 seconds a second time.
  5. Remove Red wire jumper. Turn key ON then OFF, count 10 seconds a third time. ECU is reset.
  6. A TPS Learn Procedure must be performed after ECU reset.

Tools required

  • Red wire jumper (Kohler EFI service kit) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.