Home›Repair guides›Kohler›Contactor Assembly Removal (Single-Phase Models)

Kohler — Contactor Assembly Removal (Single-Phase Models)

Repair & overhaul

From a Kohler service manual — check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • Hazardous voltage. Disconnect all power sources before opening the enclosure.

Procedure

  1. Disable the generator set and disconnect all power sources before opening the enclosure.
  2. Loosen the power terminal lugs and disconnect the normal, emergency, and load power conductors; label and tape the ends.
  3. Disconnect the contactor wiring harness from the controller at connector P13.
  4. Support the contactor and remove the corner screws securing the contactor base to the enclosure back wall.
  5. Lift and pull the contactor assembly from the enclosure.

Tools required

  • Basic electrician's hand tools

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.