Home›Repair guides›Kohler›Complete the RSA III final installation

Kohler — Complete the RSA III final installation

Installation

From a Kohler service manual covering: APM402, APM603, APM802, Decision-Maker 550, GM32644-KP1, GM62466-KP1, GM91356, KPC 1000, MPAC 1000, MPAC 1200, MPAC 1500, MPAC 750. Check it applies to your exact model before use.

Applies to: Kohler APM402, Kohler APM603

Procedure

  1. Mount the RSA III box to the wall or to the electrical box in the wall if not already done; check that the box is square.
  2. Position the RSA III front panel assembly to the box and install four self-tapping screws X-67-154; do not tighten.
  3. Center the remote annunciator in the box and square with the wall; tighten the screws.
  4. Flush mount: place wall-mounting plate GM85126 behind the RSA III front panel assembly flange.

Specs & values

  • Four self-tapping screws X-67-154

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.