Home›Repair guides›Kohler›Checking the Fuel Pressure at the Regulator

Kohler — Checking the Fuel Pressure at the Regulator

Testing & diagnosis · Fuel regulator

From a Kohler service manual covering: 14RCA, 20RCA, 26RCA. Check it applies to your exact model before use.

Applies to: Kohler 14RCA, Kohler 20RCA, Kohler 26RCA

Procedure

  1. Remove the plug from the fuel pressure port.
  2. Connect a manometer capable of measuring low pressures (3-11 inches water column) to the pressure port.
  3. When finished, replace the plug in the pressure port and check for leaks.

Tools required

  • Manometer capable of measuring 3-11 inches water column Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Kohler 14RCA →, Kohler 20RCA →, Kohler 26RCA →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →